Fisher Paykel CG305DNGX1 Installation Manual Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
7
Cooktop
To Cooktop
Regulator
Solid or Flexible
Connector
Shut-Off
Valve
Pipe Stub from
House supply
Pressure
Regulator
shows
Direction of
Gas Flow
This appliance is factory set for use with Natural Gas at 4” W.C.P. or LP
Gas at 11” W.C.P. Check the label on the underside of the appliance.
Gas regulator
For use with a gas pressure regulator as shown.
!2 CONNECT TO THE GAS SUPPLY
!3 LEAK TESTING
GAS
ON
GAS
ON
1
2
Fibre washer
Floating nut
Elbow (½ BSP external thread)
Foam Tape
Adhesive side
20 mm
50 mm
+50 mm
NG
ALL Models
Make sure the connection point will be accessible with the cooktop installed.
To enable the gas supply to be readily shut o by the customer, make sure the connection
is tted with an isolating valve close to the cooktop.
Make sure to t the supplied
washer and regulator.
Adjust to obtain a test point
pressure of 1 kPa with the two
semi-rapid burners operating at
highest setting.
Ensure the hose is long enough to allow for removal of cooktop for servicing.
Make sure the connector is located as shown in step 5 CLEARANCE DIMENSIONS.
The hose assembly must be AS/NZS 1869 Class B or D certied, with an Rp ½” (ISO 7‐1) female thread connection.
The hose assembly must be as short as practicable and comply with relevant AS 5601/NZS 5261 requirements.
The hose must not be kinked, subjected to abrasion or permanently deformed.
The hose must not be near or in contact with any hot surfaces
(e.g. base of metal hotlplate, ue, or chassis of underbench oven etc.)
If connecting the gas with a exible hose:
LPG
recessed to 50 mm
check all connections
Make sure to t the supplied
washer and test point adaptor.
Make sure the supply pressure
is regulated to 2.75 kPa, with
the two semi-rapid burners
operating at highest setting.
Washer
Washer
If converting to LPG, see 16 'Converting to a dierent gas type'
To check that the ignition system operates correctly, light each burner by itself, then all burners in combination.
Check for a well‐dened blue ame without any yellow tipping.
If any abnormality is evident, check that the components of the burner assembly are located properly
If proper operation cannot be obtained, contact your nearest F&P Authorised Service Centre.
The cooktop must not be used by the customer until proper operation has been achieved.
yellow tiplifting o
good ame
Arrow
Leak testing of the appliance shall be conducted according to the manufacturer’s instructions.
The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during
any pressure testing of that system in excess of 1/2 psi (3.5kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve
during any pressure testing of the gas supply piping system at test pressures at or less than 1/2 psi (3.5 kPa).
Maximum inlet gas supply pressure 20” W.C. (5 kPa)
Minimum gas supply pressure for regulator testing 5” W.C. Natural Gas, 12” W.C. LP Gas.
After installing the gas supply and making all connections, check thoroughly for possible leaks:
1 Turn all control dials on unit to “OFF” position.
2 Open the valve on the gas supply.
3 Using a leak detection fluid (eg Rocol leak detection spray), check each gas connection one at a time by spraying
or brushing the solution over the connection. The presence of bubbles will indicate a leak.
4 If necessary, tighten the fitting and recheck for leaks.
5 Turn on burner valve and light each burner.
6 Check for a clear blue flame without yellow tipping. If burners show any abnormalities, check that they are
located properly and in line with the injector orifice.