DATE: 24.04.2018
IMPORTANT: Throughout this guide, dimensions may vary by ±2mm (1/16'').
Read the installation guide for detailed information on installing the product.
For full installation instructions and specifications visit fisherpaykel.com
CAVITY PREPARATION
6" Professional Range
0 5 10 20
g
RDV models
f b
FINAL POSITION OF
RANGE AGAINST WALL
ELECTRICAL & GAS
RGV models
c d
e b
a
a
FINAL POSITION OF
RANGE AGAINST WALL
ELECTRICAL
GAS
inches
Model no:
RGV2-364GD-N, RGV2-364GD-L
RDV2-364GD-N, RDV2-364GD-L
Location of Electrical and Gas Supply
in
A Depth of supply area (ie maximum protrusion of
gasconnection from wall)
2''
B Distance from right hand edge of range to supply area
1 1/2''
C (RGV) Height of electrical supply area (from floor)
19''
D (RGV) Height of gas supply area (from floor)
12''
E (RGV) Width of supply area
5''
F (RDV) Distance from left hand edge of range to supply area
1 1/2''
G (RDV) Height of electrical and gas supply area (from floor)
6''
Specifications
Electrical
RGV Models
Supply
120 VAC, 60Hz
Max. Current Draw
8 amp
Service
15 amp circuit
Electrical
RDV Models
Supply
120/240 VAC, 60Hz
Max. Current Draw
21 amp
Service
0 amp circuit
Gas – Natural
Connection
1/2” NPT Minimum 5/8” dia. flex line
Supply Pressure
Supply Pressure: 6” to 9” W.C.
Gas – LP
Connection
1/2” NPT Minimum 5/8” dia. flex line
Supply Pressure*
11” to 14” W.C.
A regulator is required at the LP source to provide a maximum pressure
of 14” W.C. to the range regulator.