17
8 84” (2134mm) CAVITY – ATTACH ANTI-TIP BRACKET
IMPORTANT!
Safety requires refrigerators be stable when door and/or drawer, are open. The anti-tip bracket and fittings supplied must be fitted to the wall of the finished enclosure to withstand
a220.5lb (100kg) load. This will prevent the possibility of the appliance tipping forward, when door and/or drawer, are open.
WARNING!
Failure to follow instructions can lead to serious injury or death.
When fastening with masonry plugs and/or screws:
Ensure the screws avoid electrical, gas and water conduits.
Ensure the surface the bracket is fastened to withstands a 220.5lb (100kg) load.
Ensure light-weight masonry material such as cinder block and new concrete (no curing time) are not used in installation.
Do not use metallic materials that may corrode, stain and/or damage the enclosure
A
23/8” min.
(60mm)
overlap
Bracket
PROFILE VIEW
Subtract 61/2” (164mm) from above
finished enclosure
C
23/8” min.
(60mm)
overlap
Bracket
PROFILE VIEW
Subtract 61/2” (164mm) from above
finished enclosure
Spacer
B
23/8” min.
(60mm)
overlap
Bracket
PROFILE VIEW
Subtract 61/2” (164mm) from above
finished enclosure
Spacer installation
If a minimum 23/8” (60mm) overlap cannot be achieved we recommend
fastening a solid spacer (wooden beam etc) behind the bracket.
1
Ensure the length of the spacer corresponds to the enclosure’s width. Always
secure the spacer to existing studs on the enclosure wall (refer toC).
2
Fix bracket to the spacer with screws x4 (#10 x 40 pan head Phillips screws).
Ensure screws hold tight and the bracket overlaps the appliance when it is
positioned (23/8”min. (60mm)) for a secure hold.
Solid wall installation
1
Project the end of the above finished enclosure to the center of the back wall and
subtract 61/2” (164mm). This will locate the contact surface between the bracket
and the appliance (refer toB).
2
Mark screw locations to drill Ø1/4” x 13/8” (Ø 6mm x 35mm) deep holes. Hammer
masonry plugs into the wall until flush x4. Fix bracket to the wall with screws x4
(#10 x 40 pan head Phillips screws). Ensure screws hold tight.
For 84” (2134mm) cavity installation
Wooden/plaster board wall installation
1
Project the end of the above finished enclosure to the center of the back wall and
subtract 61/2” (164mm). This will locate the contact surface between the bracket and
the appliance (refer toA).
Ensure a structural beam/wall stud closest to the center of the wall enclosure is located.
2
Fix bracket to the wall with screws x4 (#10 x 40 pan head Phillips screws).
Ensure screws hold tight and the bracket overlaps the appliance when it is positioned
(23/8” min. (60mm)) for a secure hold.