!5 HANG NON-WATER DISPENSING DOOR PANELS
6
Once satisfied with all door panels, secure M8 studs
with M8 washer and M8 nut (refer to B). The top of the
stud must remain below the top face of the door panel.
7
Secure side bracket forks by tightening side screws (C).
Repeat this process for all door panels.
Note: for depth adjustment loosen side screws x4,
adjustpanels and then retighten oncesatisfied.
Note: further adjustment of door panels can be achieved by removing door panels
then loosening the fixing screws for the hanging bracket and moving the bracket
sideways to suit.
8
Loosely install locking bracket into the pocket on the underside of the door using a
M8 stud (D). Slide the locking bracket out until it touches the back of the door panel.
Screw in place using a #8 x 16 screw through one of the three slotted holes. Fully
tighten the M8 stud.
5
All door panels have full axis adjustment to ensure
they are flush with adjacent walls. To adjust the
height of each panel turn clockwise to raise stud or
counter-clockwise to lower stud (refer to A).
B
A
IMPORTANT!
Remove protective film from white product
doors before hanging door panels.
1
Hang all door panels onto M8 studs and align
the side bracket forks onto the refrigerator door.
Ensure the forks are positioned around the
body of the side screws (M5 x 10 pan head
Phillips screw).
2
Push the product until the door panels are flush.
Depending on your installation design this will
be flush with your adjacent cabinetry or your
framework. Place a ruler on the front of the
product to check flushness top and bottom, left
and right (refer to drawing below).
3
Ensure the gap between the top of the door
panel and the top cabinetry is no greater
than 1/4” (7mm). To reduce this gap, raise the
product by turning all four adjustment nuts the
same number of turns.
IMPORTANT!
Failure to follow these steps can lead to
difficulties in door panel adjustment and
cosmetic cap fitment.
For Fisher & Paykel EZKleen stainless steel and DCS stainless steel door panels and custom panels.
Place a ruler on the front of
the product to check flushness
top and bottom, left and right.
4
Lock top panel side screw to allow
opening the door without affecting
adjustment.